Non-Contact Voltage Portal Interface Points

Mitchell Part Number: GCI-R1A003

See other products by Mitchell Instruments

Availability: Typically In stock.

$69.95
Add Items to Cart Add to Cart

Quick Overview

The ChekVolt, a non-contact voltage portal, reduces arc flash risk while increasing electrical safety and productivity by providing maintenance personnel a no-touch voltage portal on the outside of grounded metallic electrical enclosures. The ability to preverify electrical isolation before opening a panel puts an additional safety measure between electricians and hazardous voltage.

Be the first to review this product

Integral 6’ lead wire which installs in a ½” hole for easy installation. The rugged polycarbonate construction for safety is UV outdoor rated so you can mount it anywhere. The ChekVolt interface, installed on an electrical panel, allows maintenance people to use any noncontact voltage detector pen to check line voltage before and after they open the main disconnect. The standard yellow name labels (as seen on back) help remind personnel to pre-verify every voltage point before accessing the panel interior. The ChekVolt® simply extends the line voltage from the main disconnect (or other voltage source) through a wire into an encapsulated non-metallic assembly fastened to the enclosure exterior. The ChekVolt is sold with three interface points and one three-point label.

Product Includes Three ChekVolt Interface Points and One Three-Point Label
Specifications

The ChekVolt® interface installs into a 1/2" (13mm) drilled hole. All nameplates simplify field installations with drilling locator tabs. Install Qty (3) R-1A for 3-phase applications.

Operating instructions:
1.) Verify proper operation of . With the Isolator closed and the electrical panel powered, verify the NCVD indicates voltage when completely inserted into the bottom of the recessed area of the interface (figure 1). If the NCVD does not indicate voltage, then proceed with Lock-out Tagout (LOTO) procedure as per NFPA 70E Annex G or other approved procedure).
2.) Open the isolator, insert the NCVD individually into the indent of each installed interface (one for each phase). If the phases have been isolated, then the NCVD should not sense voltage on each interface and the panel has been pre-verified. From here on follow approved electrical LOTO procedure.

Shipping Weight 1.0000
Manufacturer Mitchell Instruments
MPN R1A003
Mitchell Catalog Number 8er1a003, 9er1a003

Product Tags

Add Your Tags:
Use spaces to separate tags. Use single quotes (') for phrases.


 

My Cart

You have no items in your shopping cart.

Compare Products

You have no items to compare.

 
  Loading...
Thank You For Shopping with Mitchell Instrument Company Inc.® - 1570 Cherokee St. San Marcos CA 92078 - Call Toll Free: (888) 270 2690 - Fax (800) 648 2411